Known Issues
The following are known issues (and “wish list” items!) when running version 8 of this module with version
2.5.171 on the Roku Soundbridge. Each of these issues is due to some shortcoming in the Roku firmware and
has been reported to Roku Labs.
Shuffle and Repeat Commands Cause Error Messages
The Soundbridge will report an error condition when polled for transport state after setting the shuffle or
repeat state using the remote control or RCP. To avoid this issue, the Crestron module sends a quick
Pause/Play sequence after each shuffle or repeat command to reset the transport state flag in the Roku.
If you execute a shuffle or repeat command from the IR remote, however, the module will report an
error condition each time it polls for the transport state.
No Unsolicited Feedback
No unsolicited feedback is provided by the SoundBridge. Therefore, the module must poll the
SoundBridge constantly. This means that it may take a second or two before the feedback will update
when a new song comes on.
No Power Status Feedback
There is no power status feedback available.
Server Selection or Disconnect Won’t Work if Server Selected from Remote Control
If you select a server (e.g. library or Internet radio station) using the remote control, the Crestron
module will not be able to disconnect from the server or connect to another server. If you make your
initial server selection with the Crestron module, you will be able to disconnect or select another server.
Searching for AM, FM, or Internet Radio stations
The SoundBridge does not support searching for radio stations.